ChillerROI

  • Overview
  • Downloads
  • Contact us

Compare chiller benefits

Purchasing a chiller for an office, school, hospital, data center, or other large building is a complex decision with far-reaching consequences. You not only need to consider the initial investment and installation parameters but also think long-term to keep monthly energy costs as low as possible and minimize environmental impact. 

The Danfoss ChillerROI app simplifies the decision-making process by allowing you to estimate the return on investment (ROI) using a few pieces of basic information. Simply enter the parameters into the app, and you’ll get a side-by-side comparison that displays the expected long- and short-term costs. Then, you can choose the best chiller for the situation.

You can also export the results for use in your own reports.

The ChillerROI app calculates ROI based on:

  • Chiller efficiency data (IPLV)
  • Capex cost ($/ton)
  • Chiller capacity
  • Initial cost
  • Local electrical rates
  • Expected hours of operation

Whether you are installing a chiller at your own facility or sharing the benefits of your chiller system with a customer, the ChillerROI app helps make the decision process quick and easy. Download it today for free to get started.

Downloads

How to use

To get started, input the baseline data for the project, including capacity, running time (hours per year), and cost of energy. The data can be changed by sliding the target to the correct value. You can also change the value manually by pressing and holding the default value for a few seconds.  This will cause the keypad to show up and you can enter the value.

Next, input the efficiency (IPLV) and Capex cost ($/ton) for chiller A. Chiller A should be the least efficient of the two models being compared. Finally, the same information should be entered for chiller B, the more efficient chiller.

The app will then display the return on investment (ROI) in graphical form at the top of the screen.

You can also view the data in a summary report by selecting the menu located on the top right of the screen and then selecting "export." You can switch the display to metric units in this section as well.

Contact us

For further information, please contact us.

Disclaimer

ChillerROI ("the Application") is provided on an "as is" and "as available" basis for the intended purposes as determined by Danfoss only and any use thereof is at the user's sole risk. The Application and results and information generated thereby cannot substitute technical advice but must be verified by the user, they are not promises and should not be relied on as accurate data or analyses.

Danfoss disclaims all warranties and conditions regarding the Application, whether express, implied, or statutory, including, but not limited to, conditions of merchantability, satisfactory quality, and fitness for a particular purpose, accuracy, and non-infringement of third parties' rights. Danfoss does not warrant that the Application will meet your requirements or that the operation thereof will be uninterrupted or error-free.

To the extent not prohibited by law, in no event shall Danfoss be liable for any direct, special, indirect or consequential damages, whatsoever, including, without limitation, damage to property, damages for loss of savings or profits, or loss of data arising out of any use of the Application.

Please visit https://www.danfoss.com/en/products/compressors/dcs/turbocor for more information about Turbocor® compressors.

Please review the Danfoss Privacy Policy: https://www.danfoss.com/en/terms/privacy/

ChillerROI support, please email product.support@danfoss.com

The ChillerROI app belongs to Danfoss A/S.