Milk cooling tanks ensuring accurate temperature control
Dairy farms rely on highly efficient cooling of the milk to keep the milk at a consistent temperature of about 4°C in the milk tanks until the milk is collected for further processing.
Milk is stored at the farms in either closed or open milk tanks.To maintain the quality of the milk it is quickly cooled from 38°C leaving the cow to 4°C in the milk tank. The milk tank is typically equipped with a mixer to accelerate the cooling process and homogenize the milk.
In the Danfoss range of solutions for efficient cooling of milk tanks you will find solutions suited for any tank size, any evaporation temperature and for all types of refrigerants, including low GWP refrigerants. The accurate temperature control of the Danfoss components also ensures that the milk does not freeze to avoid depleting of the fresh milk quality. Our solutions are tailored to comply with national/regional legislation.
Features and benefits
Air cooled condensing units especially suited for milk tanks, equipped with hermetic compressors, mainly reciprocating and scroll compressors, sometimes semi hermetic compressors
Customized condensing units sized to fit tank dimensions and ambient temperatures
A wide range of controls to secure reliable refrigeration
Long service life
Related products
-
if (isSmallPicture) {
; } else if (isBigColumns) { } else { }Sight glassesSGP is a series of sight glasses for high pressure applications (Max Working Pressure 52 bar/754 psig). SGP is available in versions optimized for refrigerants with mineral oil e.g. HCFC, and in versions optimized for non-flammable HFC refrigerants. SGP is available with flare, solder and socket connections, and with and without moisture indicators.
-
if (isSmallPicture) {
; } else if (isBigColumns) { } else { }Shut-off ball valves for refrigeration, GBCGBC ball valves are manually operated shut-off valves suitable for applications where bi-directional flow is a requirement. GBC valves are approved for applications in liquid, suction, and hot gas lines in refrigeration and air conditioning systems.
-
if (isSmallPicture) {
; } else if (isBigColumns) { } else { }Refrigeration temperature sensorsRefrigeration temperature sensors are used for applications within air-conditioning as well as commercial and industrial refrigeration applications. The Pt 1000 sensor element meets the DIN/IES 751 class B requirements and ensures an accurate and reliable temperture signal applicable for regulation, safety and data logging.
-
if (isSmallPicture) {
; } else if (isBigColumns) { } else { }Optyma™ iCO₂ 4.6kW MTOptyma™ iCO₂ 4.6 kW (MBP) condensing unit is a robust and low-noise solution for natural refrigerant R744 compatibility.
-
if (isSmallPicture) {
; } else if (isBigColumns) { } else { }Micro Plate™ technologyThe next step in application-focused, high-performance heat exchanger
design, Micro Plates™ are a revolutionary technology, specially created for
district energy solutions and for use in heat pumps, chillers, and close control
systems for cooling capacities up 800 kW / 225 TR.
Learning
Do you want to learn more about milk cooling tanks?
Contact us
For further information, please contact us.