Danfoss AB-QM was the first of its kind control valve for HVAC heating and cooling applications. It is a control valve with automatic flow limitation and built-in differential pressure control functioning over the control valve. The result of this concept is a high performing control valve with a – still - unique valve authority of 100%. The design flow can easily be set to the needed amount by using a 10% or 20% to 100% scale. Simply setting the design flow replaces traditional commissioning processes, gives a much more accurate control and avoids Kv calculations for system designers.
View the 3D model
When equipped with a Danfoss actuator, PICVs increase the energy efficiency and improve the indoor climate. The AB-QM is mainly used for air handling units, climate ceilings, fan-coil units and other terminal units in HVAC heating and cooling systems.
Features and benefits
Easy setting and sizing
Selecting the right AB-QM is much less complicated than sizing and selecting conventional control valves. Once the design flow is determined the matching AB-QM can be selected, no additional Kv and authority calculations are required.
100% authority
Having a 100% valve authority increases the control quality and precision, also at low flow requirements. This creates a better comfort in the building, as well as increasing the energy savings.
Perfect control
By providing the right flow at the right time, the AB-QM optimizes chiller and boiler efficiency and reduces pumping costs. In addition, the actuators need to make much less movements, increasing the lifetime value and lowering the Total Cost of Ownership.
New: AB-QM 4.0
Get ready for the next level value of your PICV designs.
Documents
Type | Name | Language | Valid for | Updated | Download | File type |
---|---|---|---|---|---|---|
Brochure | AB-QM - Millions of reasons to choose the best | English | Multiple | 02 May, 2018 | 5.0 MB | |
Brochure | Energy saving solutions for renovation of heating and cooling systems | English | Multiple | 10 Sept, 2014 | 5.9 MB | |
Brochure | Hotel application brochure | English | Multiple | 03 Sept, 2014 | 654.7 KB | |
Application guide | HVAC Application guide | English | Multiple | 26 Oct, 2020 | 19.4 MB | |
Brochure | Hydronic Balancing & Control product overview | English | United Kingdom | 11 Nov, 2014 | 7.1 MB | |
Brochure | Hydronic Balancing & Control product overview | English | Multiple | 12 Dec, 2016 | 1.1 MB | |
Case story | NovoCon - outstanding HVAC flexibility after office building renovation | English | Multiple | 28 Sept, 2020 | 960.1 KB |
Software
Danfoss SET 365 software
Our advanced Danfoss SET 365 3D design software will help you to design and calculate HVAC systems with Danfoss products. A 1-year subscription is FREE available for students, designers and other interested professionals.
Case studies
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }HVAC control at Katowice business centre, Poland
Katowice Business Centre is a modern office building where Danfoss hydronic balancing solutions are used; AB-QM balancing and control valves in combination with revolutionary NovoCon® actuators.
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }Energy comfort in Prime Tower, Zurich, Switzerland
The Prime Tower in Zurich is a building of many records. With its 126 meters it is the tallest building in Switzerland with 36 floors and 40,000 square meters accommodating mostly offices. And with its more than 6,000 AB-QM valves it is also one of the biggest heating and cooling installations ever designed and installed by Danfoss.
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }Hydronic balancing in SAMBA bank head office, Riyadh, UAE
At the heart of the new King Abdullah Financial District in Riyadh stands the impressive SAMBA head office. The 40-storey building represents a landmark in sustainable architecture and engineering and forms an attractive work space for the 800 people working in the SAMBA Financial Group head office.
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }Hydronic balancing in Burj Khalifa, Dubai, UAE
Burj Khalifa, the world’s tallest building, is located in Dubai, United Arab Emirates (UAE). With a staggering 160 floors, reaching 828 metres, the building takes your breath away. Burj Khalifa is not only a world famous skyscraper, but also a building complex in downtown Dubai with residential buildings, office buildings, hotels and shops.
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }Balancing valves in Sky Tower, Wroclaw, Poland
The tallest building of the EU now resides in Wroclaw in Poland. As a beautiful landmark to modern architecture, high user comfort and sustainable practice, the 212 meter high Sky Tower forms the pleasant setting for thousands of people living and working in the building.
Videos
Tender texts
3D models and drawings
Related products
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }NovoCon® S Digital Actuator
With NovoCon® S Danfoss revolutionizes the way hydronic balancing and HVAC control work together. The first of its kind digital HVAC actuators are directly connected with a Building Management System (BMS). This enables System Integrators to design state-of-art, Internet of Things (IoT) solutions.
-
if (isSmallPicture) { ; } else if (isBigColumns) { } else { }AB-QM 4.0 Pressure Independent Control Valves (PICV) DN15 - DN32
AB-QM 4.0 Pressure Independent Control Valves (PICVs) are the successor of Danfoss AB-QM. They offer best-in-class specifications and easy installation. The scaling- and clogging resistant design secures and outstanding reliability and long lifetime. The required design flow can easily be established by turning the setting wheel on top of the valve to a presetting between 10-100% of the nominal flow. A wide variety of on/off, modulating and digital actuators is available to accurately control the flow through the valves.
Software
News
Coming soon...
Coming soon...